Questions about how individual parts of claim 1 might be changed. A question may describe something different from what the claim language recites, or a version of it; no view is offered on which.
1.1Model from projection images
What ifWhat if the tissue model came from two calibrated radiographs?
Claim language“formed based on medical volume data”
For a long bone, an operator traces the bone outline in two approximately perpendicular projections, and software fits a statistical bone surface to both outlines. The operator marks a visible treatment focus in both views, and software triangulates its center and stores a treatment region around that center in the fitted model.
1.2Fixed probe with tissue motion
What ifWhat if a rigid mount held the probe at a fixed pose and a linear stage moved the tissue through the imaging plane?
Claim language“detects a position and an orientation”
A keyed mount fixes the probe relative to the frame, and a motorized stage translates a supported limb perpendicular to the imaging plane. The reconstruction software assigns each frame a slice position from the stage encoder and the fixed geometry of the mount.
1.4Alignment by region overlap
What ifWhat if the system aligned the model and the ultrasound volume by matching segmented tissue regions?
Claim language“a plurality of feature points included in the three-dimensional model”
The system stores the modeled organ as a binary mask and segments the same organ in the ultrasound volume. A multiresolution optimizer varies translation and rotation to maximize overlap between the masks.
1.5Target traced in ultrasound
What ifWhat if the operator defined the target directly on ultrasound slices?
Claim language“based on the treatment target portion included in the three-dimensional model”
The operator traces the boundary of a sonographically visible target on selected slices and adds contours where its shape changes rapidly. The software interpolates the contours between slices and fills the resulting region to produce a three-dimensional target mask.
Section 2 · machine-generated
Variations
Further arrangements of the same subject matter, described here as of the publication date at the foot of this page.
Other field of use
Ultrasound mapping of composite panel defects
A three-dimensional model derived from industrial X-ray tomography contains a segmented delamination region in a composite panel. A tracked immersion ultrasound probe scans the panel and reconstructs a volume from pulse-echo signals and probe poses. Paired hole centers and edge junctions register the model to the ultrasound volume, and the resulting transform maps the delamination region into the scan for repair planning.
Component substitution
Electromagnetic tracking for a handheld probe
A six-degree-of-freedom electromagnetic sensor fixed to the ultrasound probe supplies probe pose relative to a field generator mounted beside the examination table. A calibration transform relates the sensor frame to the ultrasound image plane, and timestamps associate each image slice with an interpolated sensor pose. The reconstruction software places the slices in the generator frame, aligns paired anatomical landmarks, and transforms the model target into that frame.
Parameter or scale variation
Fine voxel reconstruction for superficial targets
A tracked linear-array probe records 80 parallel B-mode slices at 0.5 mm spacing across a superficial target. The reconstruction software resamples the slices into a 50 × 40 × 40 mm grid with 0.5 mm isotropic voxels. A rigid transform fitted to six paired landmarks distributed across the scanned tissue maps the model target onto the grid using nearest-neighbor interpolation.
Combination with existing systems
Target overlay for tracked needle guidance
An image-guided needle navigation system receives the reconstructed ultrasound volume and registered target mask. A position and orientation sensor on the needle hub shares the probe tracking frame, and a calibration transform locates the needle tip and axis relative to that sensor. The navigation display overlays the tip and projected needle axis on ultrasound slices and shows their positions relative to the target boundary.
Automated or data-driven variant
Automatic registration from vessel branch points
Segmentation software extracts vessel lumen masks from a preprocedural volume and a tracked three-dimensional ultrasound scan of the same tissue. The software computes vessel centerlines and pairs branch points using branch angles and distances to neighboring junctions. Random sample consensus selects geometrically consistent pairs, and a least-squares rigid fit maps the model target into the ultrasound volume.
Deformation correction from tracked probe pressure
A force sensor between the probe housing and its handle records contact force alongside ultrasound frames and probe poses during two sweeps at different compression levels. The software reconstructs both volumes and estimates local tissue displacement by matching ultrasound intensity patterns between them. After landmark registration to the lower-compression volume, the software interpolates the measured displacements at the current contact force and warps the registered target mask accordingly.
Specific version of a part
Ultrasound after treatment begins
After the first application, the probe acquires a tracked sweep while energy delivery is paused. The system registers the reconstructed volume to the tissue model using landmarks outside the treated region and displays the planned target for positioning the second application.
Coordinate transfer through a frame
A frame fixed to a limb carries markers visible in the planning scan and a tracked marker array with a calibrated offset from those markers. With the frame still attached, the system composes the model-to-frame transform, the tracked frame-to-probe transform, and the probe calibration to express model coordinates in the ultrasound volume.
Labeled model from magnetic resonance
The acquisition unit reads a magnetic resonance volume together with its voxel spacing, origin, and axis directions. It loads organ and treatment target masks drawn on that volume and stores both labels in the same physical coordinate system.
Optical tracking of probe pose
A rigid cluster of four reflective spheres attaches to the probe housing. Two infrared cameras triangulate the sphere centers, and a rigid fit estimates the position and orientation of the probe at each frame timestamp.
Tracked freehand volume reconstruction
Before treatment, a linear array collects echo frames during a freehand sweep, and the system records a synchronized probe pose for each frame. Using the calibrated transform from the image plane to the probe, the reconstruction deposits frame samples onto a cubic voxel grid referenced to the probe pose at the start of the sweep.
Registration using vessel branch points
An operator marks four corresponding vessel bifurcations distributed through the modeled tissue and the ultrasound volume. The conversion unit fits a rigid rotation and translation that minimize the sum of squared distances between paired points and applies the resulting transform to the model.
Section 3 · quoted from USPTO records
Other work
Passages reproduced word for word from two earlier-published U.S. patent documents, placed beside the language of claim 1. No characterization is offered. Each passage is marked A or B for the document it comes from; ¶ numbers are the paragraph numbers in the USPTO’s published full text of that document.
1.1a three-dimensional model acquisition unit that acquires a three-dimensional model of a target tissue, which is formed based on medical volume data acquired by a medical apparatus and is defined in a model coordinate system, the three-dimensional model having information indicating a region occupied by a treatment target portion of the target tissue;
A “volume” of medical images is a three-dimensional representation of the internal anatomical structure of the biological entity which is made up of stacks of two-dimensional slices, where the slices may be individual medical images captured by medical imaging technology.
B · US 11,688,063 B2 · ¶ 50
1.2a probe position/orientation detection unit that detects a position and an orientation of an ultrasound probe;
1.3a volume data acquisition unit that acquires ultrasound volume data, which is formed based on reception signals obtained by transmitting and receiving ultrasound to and from the target tissue with the ultrasound probe prior to treatment on the treatment target portion, the ultrasound volume data being defined in an ultrasound data coordinate system based on the position and the orientation of the ultrasound probe in a case in which the reception signals are acquired;
The display 138 may display patient information, one or more ultrasound images and/or videos, components of a graphical user interface, one or more 2D, 3D, or 4D ultrasound image data sets from ultrasound data stored in the memory 106 or currently being acquired in real-time, anatomical measurements, diagnosis, treatment information, tags, and/or the like received by the display 138 from the controller circuit 102.
A · US 2019/0008480 A1 · ¶ 41
1.4a coordinate system conversion unit that defines the three-dimensional model in the ultrasound data coordinate system by performing alignment between the three-dimensional model and the ultrasound volume data based on a plurality of feature points included in the three-dimensional model and a plurality of feature points included in the ultrasound volume data; and
The systems and methods compare the first ultrasound image feature in the current ultrasound image with related ultrasound image features in the plurality of prior ultrasound images to identify candidate ultrasound images.
A · US 2019/0008480 A1 · abstract
1.5a treatment target portion specifying unit that specifies a region of a treatment target portion in the ultrasound volume data based on the treatment target portion included in the three-dimensional model defined in the ultrasound data coordinate system.
With regard to the illustrative embodiments, the ML/DL computer models of the AI pipeline are executed, after configuration and training through ML/DL training processes, and perform complex computer medical imaging analysis to detect anatomical structures in input medical images and generate outputs specifically identifying target biological structures of interest (hereafter assumed to be liver lesions for purposes of description of example embodiments), their classification
B · US 11,688,063 B2 · ¶ 49
An empty cell means only that no passage was reproduced there.
Why these two documents?
Only Document A has a passage for 1.31.4. Only Document B has a passage for 1.11.5.
Additional background
Sentences reproduced word for word from these documents that state a problem, a purpose or benefit, a field of use, or an application or improvement.
Liver lesions are typically only identifiable by having a medical imaging test, such as an ultrasound, magnetic resonance image (MM), computerized tomograph (CT), or positron emission tomography (PET) scan, for example.
B · US 11,688,063 B2 · ¶ 3
Related claim parts: 1.3
The clinician compares ultrasound images between ultrasound exams to monitor physiological, pathological, and/or function changes in the patient over time.
A · US 2019/0008480 A1 · ¶ 2
The clinician selects one of the prior ultrasound images that matches the select ultrasound image, which is a labor and time intensive manual process.
A · US 2019/0008480 A1 · ¶ 2
Such medical imaging tests must be viewed by a human medical imaging subject matter expert (SME) who must use their own knowledge and expertise as well as human ability to see patterns in images, to determine if the medical imaging test shows any lesions.
B · US 11,688,063 B2 · ¶ 3
By providing an architecture in which an ensemble of differently trained decoders are provided with counterbalanced training, a more accurate identification of lesions is made possible where considerations of specificity and sensitivity are balanced and optimized in the lesion detection.
B · US 11,688,063 B2 · ¶ 6
Cite aspatent.fyi, US 2026/0363660 A1, claim 1, first published 2026-11-22T16:44:21-05:00, https://patent.fyi/US20260363660/, SHA-256 6c8ad5d560a4c4d0dde98e8b789b00e51df08d066c0ddeab57ed90dc460befbf