Section 1 · machine-generated

What if?

Questions about how individual parts of claim 1 might be changed. A question may describe something different from what the claim language recites, or a version of it; no view is offered on which.

1.1Pre-recorded digital baseline expression profile

What ifWhat if the workflow omits preparing a physical control cell sample and uses a stored reference expression database for normalization?
Claim language“a control sample cancer cell”

A laboratory information system stores baseline transcript counts per million for the cell lineage recorded from untreated cultures under matching nutrient and temperature conditions. The assay loads these numeric reference values directly into the analysis software alongside the treated sample readouts. Normalization divides each treated transcript count by the stored reference value to yield relative expression ratios without maintaining a parallel untreated dish.

1.1Single monolayer under spatial power gradient

What ifWhat if one continuous cell monolayer receives a spatially varying intensity profile across a single dish without preparing separate discrete samples?
Claim language“a first sample cancer cell to an Nth sample cancer cell”

A single culture dish holds a uniform confluent monolayer of tumor cells mounted on a terahertz-transparent quartz slide. A wedged absorbing filter placed in the collimated beam path attenuates the wave linearly along one axis, creating a continuous spatial power gradient across the dish. Spatially resolved transcript imaging maps gene expression at micron coordinates along the gradient axis to identify the local intensity corresponding to the target expression level.

1.2Focused pulsed acoustic wave stimulation

What ifWhat if focused pulsed ultrasonic waves modulate gene expression across the sample cells rather than terahertz waves?
Claim language“terahertz waves”

A piezoelectric transducer array coupled through a degassed water bath directs pulsed acoustic beams at 1.5 megahertz into each culture well. Mechanical radiation force and microstreaming shear stress deform the nuclear lamina and alter chromatin accessibility at promoter regions. Varying the acoustic pressure amplitude between 50 and 400 kilopascals across wells produces distinct transcriptional responses without thermal denaturation.

1.2Fixed power with varied carrier frequency

What ifWhat if each sample receives radiation at one constant power level while the carrier frequency steps across distinct values?
Claim language“with different powers”

A tunable continuous-wave source holds output power constant at 20 milliwatts using a closed-loop attenuator and thermal power meter. A frequency synthesizer tunes the beam across discrete frequencies from 0.5 to 2.5 terahertz in 0.2 terahertz increments for successive sample wells. Different carrier frequencies couple selectively to distinct vibrational modes of methylated cytosine bases and surrounding hydration shells, shifting demethylation rates across samples.

1.3Direct DNA methylation level assay

What ifWhat if the comparison directly measures DNA cytosine methylation density across the genome rather than detecting expression of a predetermined gene?
Claim language“detect an expression level of a predetermined gene”

Genomic DNA extracted from each irradiated sample undergoes chemical bisulfite conversion, which converts unmethylated cytosine residues to uracil while leaving 5-methylcytosine intact. High-throughput short-read sequencing aligns the converted fragments to a reference sequence and computes the methylation percentage at each cytosine-guanine site. Comparing site-specific methylation percentages against the untreated baseline identifies the irradiation setting that produces the target epigenetic state.

Section 2 · machine-generated

Variations

Further arrangements of the same subject matter, described here as of the publication date at the foot of this page.

Other field of use

Terahertz gene modulation in industrial microbial fermentation strains

A bioreactor calibration line prepares a control sample and N test aliquots of a filamentous fungus or yeast production strain suspended in low-absorption aqueous media inside quartz cuvettes. A continuous-wave terahertz emitter irradiates each test aliquot at a distinct output power level to alter DNA methylation states across promoter regions of secondary metabolite synthesis genes. Quantitative reverse transcription polymerase chain reaction compares transcript abundance in each irradiated aliquot against the control sample to identify the power setting producing a target enzyme expression level. A flow-through quartz irradiation cell mounted upstream of the main fermentation tank then exposes the inoculum stream to that selected power level to set the desired metabolic gene expression profile.

Terahertz epigenetic control during stem cell lineage differentiation

A regenerative medicine cell-processing station applies the calibration and dosing sequence to cultured human pluripotent stem cells rather than cancer cells to regulate lineage-specific transcription factors. A reference well and N calibration wells seeded on terahertz-transparent silicon substrates receive stepped terahertz powers from a backward-wave oscillator to induce targeted promoter demethylation without chemical differentiation reagents. Single-cell transcript counting compares lineage marker expression in each irradiated calibration well against the reference well to select the power level that yields the desired differentiation state. A large-area terahertz horn antenna then irradiates a production batch of stem cells at that selected power level to drive uniform gene expression across the culture.

Component substitution

Pulsed broadband emitters replacing continuous power-stepped wave sources

A photoconductive antenna driven by an ultrafast fiber laser replaces a single-frequency continuous-wave terahertz generator in the irradiation stage. An optical delay line and a set of bandpass mesh filters split the broadband terahertz pulses into N discrete spectral bands centered on specific DNA methyl-group vibrational modes while keeping average power constant. Whole-genome bisulfite sequencing and transcript quantification compare each spectrally filtered cancer cell sample against an unirradiated control to map demethylation and gene expression per frequency band. The irradiation assembly then locks onto the mesh filter band corresponding to the target expression level and directs those filtered pulses onto the target cancer cell population.

Parameter or scale variation

High-density multiwell power sweeps with sub-minute exposure intervals

A 96-well cyclo-olefin polymer plate holds 16 unirradiated control wells and 80 sample wells containing cultured epithelial carcinoma monolayers covered by a 50-micrometer layer of culture medium to limit water absorption. A motorized stage steps each sample well beneath a 1.6-terahertz beam across 20 power levels ranging from 0.5 milliwatts to 40 milliwatts in 2-milliwatt increments, with each exposure lasting 30 seconds at a stage temperature of 37 degrees centigrade. Immediately following exposure, quantitative transcript profiling of lysates from all 80 wells computes expression ratios relative to the 16 control wells. A collimated beam of 15 millimeters in diameter then irradiates a 10-million-cell target culture dish at the selected power density for 30 seconds to reproduce the measured expression level.

Combination with existing systems

Microfluidic cell sorting coupled with inline terahertz dosing

A polydimethylsiloxane microfluidic chip with an embedded quartz window integrates the terahertz calibration and target irradiation stages directly upstream of a fluorescence-activated cell sorter. Hydrodynamic focusing aligns single cancer cells into a laminar stream through N parallel microchannels, where a beam splitter and variable attenuators deliver a distinct terahertz power level to each channel while one bypass channel serves as the control. Downstream optical detectors measure fluorescently tagged surface proteins driven by the target gene in each channel and route the single-cell intensity data to a comparator against the control channel. Once the comparator identifies the channel power that achieves the preset fluorescence ratio, a pneumatic valve directs the bulk target cell suspension through a main irradiation microchannel set to that exact power before sorting.

Automated or data-driven variant

Closed-loop regression controller for adaptive terahertz power selection

A robotic liquid handler, a motorized variable optical attenuator, a pyroelectric power meter, and a microplate luminometer connect to a central control computer running a regression model. The controller initiates a sparse sweep across six initial terahertz power settings, records actual delivered power from the pyroelectric sensor, and ingests normalized reporter gene luminescence readings against unirradiated control wells. A nonlinear curve-fitting algorithm updates a dose-response function relating delivered terahertz power to gene expression level and computes the exact continuous power value needed to reach a specified expression target between tested calibration points. The control software commands the motorized attenuator to that computed power setting, verifies output stability with the power meter, and triggers irradiation of the target cancer cell plate.

Specific version of a part

Optical rectification source with wire-grid attenuator

A femtosecond near-infrared laser pumps a nonlinear lithium niobate crystal in a tilted-pulse-front geometry to generate pulsed terahertz radiation centered at 1.6 terahertz. A pair of rotatable metallic wire-grid polarizers positioned in the collimated beam path adjusts the average beam power delivered to each sample well across discrete steps from 1 to 20 milliwatts. Off-axis parabolic gold-coated mirrors direct the beam upward through the bottom of each culture well for a fixed 30-minute exposure per sample.

Quantitative reverse-transcription polymerase chain reaction assay

Total ribonucleic acid is extracted from the untreated control cells and each irradiated sample using silica-membrane spin columns after a 6-hour post-irradiation incubation. Reverse transcriptase synthesizes complementary deoxyribonucleic acid, and a thermal cycler amplifies the target gene alongside an internal glyceraldehyde-3-phosphate dehydrogenase reference using sequence-specific oligonucleotide primers and a fluorescent intercalating dye. Cycle threshold differences between each irradiated sample and the untreated control yield the relative fold-change in expression of the target gene.

Automated stage with closed-loop power stabilization

A motorized two-axis translation stage positions the target cancer cell culture vessel at the focal plane of the parabolic mirror assembly. A calibrated pyroelectric detector samples 5 percent of the beam via a high-resistivity silicon beamsplitter and feeds a proportional-integral controller that locks the output power to the selected sample power level within 1 percent tolerance. The beam irradiates the target cell population at the duration and ambient temperature matching the calibration run to reproduce the predetermined gene expression level.

Cite aspatent.fyi, US 2026/0366006 A1, claim 1, first published 2026-11-23T19:48:44-05:00, https://patent.fyi/US20260366006/, SHA-256 99eb0ebf180501bc6ac50373844172f95bca2607ec2945f8fc3dc9ddc2fb2d36