Questions about how individual parts of claim 1 might be changed. A question may describe something different from what the claim language recites, or a version of it; no view is offered on which.
1.1Photon detection across a window
What ifWhat if a single fluorescent molecule sent photons through a transparent window to a photodiode?
Claim language“contacting a molecular sensor with at least one charge modulator”
An excitation laser illuminates a dilute solution in a confocal volume, where individual fluorescent molecules produce bursts as they pass through. An optical filter passes the emitted light to an avalanche photodiode across the window, where each detected photon generates a current pulse.
1.1Binding shifts a cavity resonance
What ifWhat if binding shifted the resonance wavelength of an optical cavity?
Claim language“contacting generates a change in current”
A dielectric microcavity concentrates light near a surface coated with capture molecules. Binding of a single target changes the local refractive index, and a tunable laser locates the shifted resonance minimum in the transmission spectrum.
1.2Open circuit potential measurement
What ifWhat if the instrument measured an open circuit potential step?
Claim language“measuring the change in current”
A high-impedance differential amplifier measures the potential between a nanoscale sensing electrode and a reference electrode in the same electrolyte. When a charged molecule binds near the sensing electrode, its electric field shifts the electrode potential, and the amplifier records the voltage step.
1.2Mechanical resonance frequency measurement
What ifWhat if the instrument measured the resonance frequency of a suspended beam?
Claim language“measuring the change in current”
An optical interferometer tracks the vibration of a driven nanomechanical beam in vacuum. A single molecule deposited on the beam adds mass and shifts its resonance frequency, which a phase-locked loop tracks from the optical signal.
1.3Conformation from current levels
What ifWhat if each current level identified the conformation of a single molecule that stayed attached throughout the recording?
Claim language“a presence or absence of the at least one charge modulator”
A single DNA hairpin bridges two metal nanoelectrodes through terminal anchor groups. Folding and unfolding shift the junction between two conductance levels, and the current trace at fixed bias gives the dwell times of the two conformations.
Section 2 · machine-generated
Variations
Further arrangements of the same subject matter, described here as of the publication date at the foot of this page.
Other field of use
Dye monitoring in textile rinse water
A silicon nitride nanopore separates two electrolyte chambers, with diluted textile rinse water introduced into the upstream chamber. The target is a charged synthetic dye that produces a transient drop in ionic current when it enters the pore. A current amplifier records the drops, and the detector counts events within amplitude and duration windows established with a reference solution of the dye and a dye-free rinse sample.
Component substitution
Electrochemical detection with a carbon nanotube
A semiconducting single-walled carbon nanotube forms the sensing element between source and drain electrodes. An insulating coating covers the metal contacts and leaves a short section of the nanotube exposed to electrolyte containing a charged synthetic porphyrin. Reversible adsorption shifts the nanotube current between two levels at fixed source-drain bias, and a threshold between the calibrated levels identifies whether the adsorption site is occupied.
Parameter or scale variation
Nanopore sensing at three bias levels
A 3 nm silicon nitride nanopore separates two chambers containing 0.1 M potassium chloride, and the upstream chamber contains a dilute solution of a charged synthetic dye. Electrodes apply 50, 100, and 150 mV across the pore in successive 1-second intervals while a current amplifier samples at 100 kHz. The detector excludes the first 10 ms after each voltage change and identifies dye events from transient current drops relative to a baseline measured separately at each voltage.
Parallel sensing with eight isolated pores
Eight electrically isolated fluidic wells each contain a membrane with one 3 nm pore and a dedicated pair of electrodes. A manifold distributes the same dilute synthetic dye solution to all wells, and separate amplifiers record pore current at 50 kHz per channel. Software applies a baseline and detection threshold to each channel and sums the resulting single-molecule event counts across the eight wells.
Combination with existing systems
Nanopore detection after capillary electrophoresis
A capillary electrophoresis system separates a mixture of charged synthetic dyes by migration time. A low-volume junction mixes the capillary effluent with supporting electrolyte and delivers it to the upstream chamber of a silicon nitride nanopore. A separate electrode pair maintains the sensing bias across the pore, and the acquisition software timestamps current drops relative to injection to assign individual events to calibrated migration windows.
Automated or data-driven variant
State inference from nanopore current
A solid-state nanopore and a current amplifier record ionic current while a charged synthetic dye passes through the pore. A two-state hidden Markov model uses Gaussian current distributions for the open and occupied states, fitted from dye-free and reference-dye recordings. Software estimates the state sequence from the sampled current and reports each occupied interval with its start time and duration.
Specific version of a part
Charged binding at a nanowire
A liquid-gated silicon nanowire carries a surface-tethered receptor that binds one charged target molecule. Binding near the channel changes the local electric field and shifts the source-to-drain current at fixed bias.
Ionic blockade in a nanopore
A fixed voltage across a thin insulating membrane drives ionic current through a nanometer-scale pore. A charged polymer enters the constriction and changes the ionic conductance until it exits.
Voltage clamp current recording
A feedback amplifier holds a fixed voltage across a membrane pore and converts the ionic current to an output voltage through a high-value feedback resistor. A low-pass filter and a digitizer capture the baseline and the current steps during individual pore occupancy events.
Occupancy from blockade duration
An event detector compares the measured pore current with a rolling estimate of the open-pore baseline. A drop that exceeds an amplitude threshold for a minimum duration marks occupancy, and recovery to the baseline marks the end of the event.
Section 3 · quoted from USPTO records
Other work
Passages reproduced word for word from two earlier-published U.S. patent documents, placed beside the language of claim 1. No characterization is offered. Each passage is marked A or B for the document it comes from; ¶ numbers are the paragraph numbers in the USPTO’s published full text of that document.
1.1contacting a molecular sensor with at least one charge modulator, wherein contacting generates a change in current;
By stressing, e.g. stretching and compressing the bonds of the SERS active substance to the substrate and/or antibody as a result of the analyte binding event detectable shifts in the SERS spectrum are induced.
A · US 9,689,801 B2 · ¶ 49
The advent of nanopores as a single-molecule platform has advanced studies of a wide range of species such as proteins, drugs, nucleotides and polymers such as RNA, DNA, polypeptides, and polysaccharides.1-7 Voltage-driven passage of analytes through a nanopore results in transient occlusion of the pore, which temporarily reduces the ionic current.
B · US 2019/0062814 A1 · ¶ 6
1.2measuring the change in current; and
The step of measuring the ionic current blockade may comprise measuring the magnitude and/or duration of the current blockade.
B · US 2019/0062814 A1 · ¶ 34
1.3correlating the change in current with a presence or absence of the at least one charge modulator, thereby sensing the single molecule.
By stressing, e.g. stretching and compressing the bonds of the SERS active substance to the substrate and/or antibody as a result of the analyte binding event detectable shifts in the SERS spectrum are induced. Surprisingly, this allows highly sensitive and specific detection of analyte binding.
A · US 9,689,801 B2 · ¶ 49
Next, we examine the detection limit of such nanopore measurements and demonstrate that individual particles from a binary mixture can be identified based on an ionic current pulse produced by a single nanopore passage of a nanoparticle.
B · US 2019/0062814 A1 · ¶ 100
An empty cell means only that no passage was reproduced there.
Why these two documents?
Only Document B has a passage for 1.2. Both have a passage for 1.11.3.
Additional background
Sentences reproduced word for word from these documents that state a problem, a purpose or benefit, a field of use, or an application or improvement.
However, under biological conditions the applications have been limited mainly due to the poor sensitivity and the need for high laser power and complicated instrumentation.
A · US 9,689,801 B2 · ¶ 7
Related claim parts: 1.2
ELISA and fluorescent immunoassay) have limited expandability in terms of the number of proteins that can be detected per assay.
A · US 9,689,801 B2 · ¶ 5
Most of these drawbacks were overcome by the development of Surface Enhanced Raman spectroscopy (SERS) where the spectral intensity is enhanced tremendously by the interaction of the SERS active analyte molecules with a substrate surface, e.g., a nanoparticle surface of copper, gold or silver.
A · US 9,689,801 B2 · ¶ 8
However, detection of a particular biomarker requires a separate procedure, which in practice limits the number of tests that can be run at the same time and hence the number of decease conditions that can be probed.
B · US 2019/0062814 A1 · ¶ 5
The systems, kits and corresponding methods provided herein address the challenges associated with reliably and efficiently detecting markers of interest, including a plurality of biomarkers.
B · US 2019/0062814 A1 · ¶ 8
Cite aspatent.fyi, US 2026/0366064 A1, claim 1, first published 2026-11-23T20:11:03-05:00, https://patent.fyi/US20260366064/, SHA-256 8a7a6e3c9a3e6da45f41c6837fdbd457044c9109be05349bbde76679ce66aba8